Simple, fast and reliable spectrophotometric methods were developed for determination of cetrizine hydrochloride in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in distilled water. The quantitative determination of the drug was carried out using the zero order derivative values measured at 234 nm and the area under the curve method values measured at 226-234 nm (n = 2). Calibration graphs constructed at their wavelengths of determination were linear in the concentration range of cetrizine hydrochloride using 2-10 μg/ml (r² = 0.9989 and r² = 0.9937) for zero order and area under the curve spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance of the proposed methods regarding the mean values and standard deviations. Developed spectrophotometric methods in this study are simple, accurate, precise and sensitive to assay of cetrizine hydrochloride in tablets.